Publication:
Thermal comfort performance of bus stops at IIUM Gombak campus

cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department0e0d97cb-0b76-483a-aa11-16e804634cfd
cris.virtualsource.orcid0e0d97cb-0b76-483a-aa11-16e804634cfd
dc.contributor.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#en_US
dc.contributor.authorIyabode, Adebayo-Aminu Sarat
dc.date.accessioned2024-10-08T07:09:25Z
dc.date.available2024-10-08T07:09:25Z
dc.date.issued2015
dc.description.abstractIn an effort to ensure a sustainable campus environment, IIUM embarked on the Green campus mission by encouraging an increase in the use of bicycles and public buses as a means to reduce pollution and ensure a friendlier and safer campus and its environs. In line with this noble cause that the university is championing, this study seeks to augment this effort by conducting research on the thermal comfort of the university concentrating on the bus stops encircling the IIUM Gombak campus. These bus stops host public buses and passengers (staffs, students and visitors) who wait for the bus to get to their destinations. For this purpose, the thermal comfort condition of bus stop encircling IIUM Gombak campus was evaluated. The research is divided into two segments; firstly, field measurements of thermal environments to calculate the human thermal comfort indices from the environmental data obtained from the bus stops, and secondly the subjective method namely field survey questionnaire, to assess the relationships between the thermal environment and the evolved subjective human reactions. The measurements were done at selected bus stops within IIUM Gombak. Then, by cross-tabulating the data using SPSS, these values were summed up in a table to indicate minimum and maximum measures. They were then compared with the current users’ perceptions of environmental values from questionnaire survey. The findings revealed that some bus stops are thermally more comfortable than the otheren_US
dc.description.callnumbert QP 82.2 T4 I97T 2015en_US
dc.description.degreelevelMasteren_US
dc.description.identifierThesis : Thermal comfort performance of bus stops at IIUM Gombak campus /by Adebayo-Aminu Sarat Iyabodeen_US
dc.description.identityt11100340955Adebayo-Aminuen_US
dc.description.kulliyahKulliyyah of Architecture and Environmental Designen_US
dc.description.notesThesis (MSBE)--International Islamic University Malaysia, 2015.en_US
dc.description.physicaldescriptionxiii,129 leaves : ill. ; 30cm.en_US
dc.description.programmeMaster of Science (Built Environment)en_US
dc.identifier.urihttps://studentrepo.iium.edu.my/handle/123456789/8840
dc.identifier.urlhttps://lib.iium.edu.my/mom/services/mom/document/getFile/dt9RB3kfE9DRorviX2xFknpGRQmEQuBX20150729091257793
dc.language.isoenen_US
dc.publisherKuala Lumpur: International Islamic University Malaysia, 2015en_US
dc.rightsCopyright International Islamic University Malaysia
dc.subject.lcshTemparature -- Physiological effecten_US
dc.subject.lcshBuilding -- Environmental engineeringen_US
dc.titleThermal comfort performance of bus stops at IIUM Gombak campusen_US
dc.typeMaster Thesisen_US
dspace.entity.typePublication
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
t11100340955Adebayo-Aminu_SEC_24.pdf
Size:
630.83 KB
Format:
Adobe Portable Document Format
Description:
24 pages file
Loading...
Thumbnail Image
Name:
t11100340955Adebayo-Aminu_SEC.pdf
Size:
3.67 MB
Format:
Adobe Portable Document Format
Description:
Full text secured file

Collections