Publication:
The impact of wider frontage design of low-cost double storey terrace house (LCDSTH) to airflow and natural ventilation in Malaysia

dc.contributor.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#en_US
dc.contributor.authorNurulashikin bte Md Taib @ Md Taliben_US
dc.date.accessioned2024-10-08T03:17:12Z
dc.date.available2024-10-08T03:17:12Z
dc.date.issued2007
dc.description.abstractThis thesis presents the results of an analysis which was done to predict the impact of wider frontage design of low-cost double storey terrace house (LCDSTH) to airflow and natural ventilation in Kuala Lumpur. The existing LCDSTH has narrow frontage and deep plan which necessitates its internal planning with partitions to divide the spaces and arranged the rooms to have single-sided openings. These arrangements have extremely limited cross-ventilation potential and caused discomfort to occupants. Due to the availability of natural ventilation from the prevailing wind in Malaysia, the LCDSTH design could be manipulated to enhance the natural ventilation to flow into the living spaces and gives cooling effect to ameliorate occupants’ thermal comfort. Predictions of the mean internal air velocity in the existing and proposed LCDSTH are used to identify the potential plan for improving thermal comfort. Computational Fluid Dynamic is chosen due to its capability in fluid dynamic studies. A specific software named FLOVENT is used to predict the internal air velocity by simulating the simplified building configuration of the existing and proposed model of LCDSTH. The outcomes of the simulated results are then compared using the graphic velocity vectors and contour from FLOVENT and also from the mean internal air velocity graph. The results show that although the proposed design with wider frontage, shorter depth plan and different building height in a staggered and checker board pattern position give the best solution as compared to the existing plan, it is not significant enough to provide to the most preferable air velocity values of 1.0 m/s for thermal comfort at every position of each unit in a row of LCDSTH. However, it does improve the performance of the mean internal air velocity in comparison with the existing double storey terrace house that has the design of narrow frontage and deep plan.en_US
dc.description.callnumbert TH7674N974I 2007en_US
dc.description.degreelevelMaster
dc.description.identifierThesis : The impact of wider frontage design of low-cost double storey terrace house (LCDSTH) to airflow and natural ventilation in Malaysia / by Nurulashikin Bte Md Taib @ Md Taliben_US
dc.description.identityt00010998124NURULASHIKINBTMDTAIBTH7674N974I2007en_US
dc.description.kulliyahKulliyyah of Architecture and Environmental Designen_US
dc.description.notesThesis (MSc. BE) -- International Islamic University Malaysiaen_US
dc.description.physicaldescriptionxxiv, 264 leaves : ill. ; 30 cm.en_US
dc.description.programmeMaster of Science in Built Environmenten_US
dc.identifier.urihttps://studentrepo.iium.edu.my/handle/123456789/7015
dc.identifier.urlhttps://lib.iium.edu.my/mom/services/mom/document/getFile/becTf3t9tSUhxfn35q6KdfE5VSog2YFL20070817082103421
dc.language.isoenen_US
dc.publisherGombak : International Islamic University Malaysia, 2007
dc.rightsCopyright International Islamic University Malaysia
dc.subject.lcshTerrace houses -- Malaysia -- Ventilationen_US
dc.subject.lcshArchitecture and climateen_US
dc.subject.lcshTerrace houses -- Designs and plansen_US
dc.subject.lcshVentilationen_US
dc.titleThe impact of wider frontage design of low-cost double storey terrace house (LCDSTH) to airflow and natural ventilation in Malaysiaen_US
dc.typeMaster Thesisen_US
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
t00010998124NURULASHIKINBTMDTAIBTH7674N974I2007_SEC_24.pdf
Size:
277.71 KB
Format:
Adobe Portable Document Format
Description:
24 pages file
Loading...
Thumbnail Image
Name:
t00010998124NURULASHIKINBTMDTAIBTH7674N974I2007_SEC.pdf
Size:
8.05 MB
Format:
Adobe Portable Document Format
Description:
Full text secured file

Collections