Publication:
Design and application of multiparameters contrast detail phantom using cylindrical double hole acrylic block for radiographic quality control tool

cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.departmentbae3018f-7341-4b4a-98c2-fb2b2e8d1a13
cris.virtualsource.orcidbae3018f-7341-4b4a-98c2-fb2b2e8d1a13
dc.contributor.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#en_US
dc.contributor.authorNur Farahana Pauzi
dc.date.accessioned2024-10-08T07:25:14Z
dc.date.available2024-10-08T07:25:14Z
dc.date.issued2016
dc.description.abstractThe consistency of contrast detail performance of imaging system can be evaluated by using Contrast Detail phantom. The analysis is always based on the human visual perception which leads to intraobserver perception bias. In addition, the wall of single drilled hole concept in commercial Contrast Detail phantom gives effect to the penetration of x -ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image but it is not visualised in the radiograph. In this study, cylindrical double hole acrylic block of Multiparameters Contrast Detail phantom has been developed which differs from the single drilled hole concept, whereby it consists of combination of different holes’ diameters and thicknesses. Results revealed that, the new design of cylindrical double hole acrylic block is able to visualise the effect of image displacement from the x-ray focal length plus measuring the off-position of anode stem, blurring effect, image distortion in terms of real shape and size, also addressing the contrast detail characteristics parameter in terms of real hole depth. The influencing factors of source-image-distance, object thickness, position of object from center beam in x-axis, sizes of hole diameter and hole depth contribute to the changes in parameters’ outcome. The measurement of pixel intensity by using software and development of algorithm for data analysis basically can reduce the human perception bias and increase the validity of the results.en_US
dc.description.callnumbert TK 8315 N974D 2016en_US
dc.description.degreelevelMaster
dc.description.identifierThesis : Design and application of multiparameters contrast detail phantom using cylindrical double hole acrylic block fror radiographic quality control tool /by Nur Farahana binti Pauzien_US
dc.description.identityt11100347313NurFarahanaPauzien_US
dc.description.kulliyahKulliyyah of Allied Health Sciencesen_US
dc.description.notesThesis (MHSC)--International Islamic University Malaysia, 2016.en_US
dc.description.physicaldescriptionxxiv, 159 leaves :ill. ;30cm.en_US
dc.description.programmeMaster of Health Sciences (Medical Imaging)en_US
dc.identifier.urihttps://studentrepo.iium.edu.my/handle/123456789/9133
dc.identifier.urlhttps://lib.iium.edu.my/mom/services/mom/document/getFile/ZbPtN24gjsOaL1ObjO31at76rN6CD70K20161124112747054
dc.language.isoenen_US
dc.publisherKuantan, Pahang : Kulliyyah of Allied Health Sciences, International Islamic University Malaysia,, 2016
dc.rightsCopyright International Islamic University Malaysia
dc.subject.lcshImaging systemsen_US
dc.subject.lcshImaging systems -- Image qualityen_US
dc.titleDesign and application of multiparameters contrast detail phantom using cylindrical double hole acrylic block for radiographic quality control tool
dc.typeMaster Thesisen_US
dspace.entity.typePublication
oairecerif.author.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
t11100347313NurFarahanaPauzi_SEC_24.pdf
Size:
390.36 KB
Format:
Adobe Portable Document Format
Description:
24 pages file
Loading...
Thumbnail Image
Name:
t11100347313NurFarahanaPauzi_SEC.pdf
Size:
3.06 MB
Format:
Adobe Portable Document Format
Description:
Full text secured file

Collections