Publication:
Accuracy and adequacy of fluoroscopic assissted percutaneous transpedicular biopsy in comparison to CT guided percutaneous transpedicular biopsy in spinal lesions

dc.contributor.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#en_US
dc.contributor.authorAbdullah A Rahimen_US
dc.contributor.supervisorZamzuri Zakaria, Ph.Den_US
dc.date.accessioned2024-10-09T04:36:52Z
dc.date.available2024-10-09T04:36:52Z
dc.date.issued2019
dc.description.abstractSpinal biopsy is the most important step of investigation in a spinal lesion to achieve an accurate diagnosis to provide an adequate treatment to the patient. Percutaneous spine biopsy has widely replaced open biopsy as it is more cost effective, less invasive, and has fewer complications than open procedures. With availability of Ct-scan, fluoroscopy and MRI, percutaneous transpedicular vertebral biopsy has now become popular as a minimally invasive technique for biopsy of spinal lesion. In this study, we compared the type of percutaneous transpedicular biopsy which were fluoroscopic and Ct-guided assisted in term of the accuracy and adequacy of the sample taken via both procedures. This is a retrospective single center study which was done by reviewing the patient’s record who had been diagnosed with a spinal lesion and undergone biopsy at Hospital Kuala Lumpur from January 2013 to December 2017. The statistical analysis of parametric data was performed using a descriptive analysis (mean and standard deviation). Correlation tests performed using Fisher Exact Test. The p value of < 0.05 is considered to indicate statistically significant difference. A total of 30 patients from each procedure was selected with the mean age of 53 years old. There were 61.7% (37 patients) patients were having spinal infection lesion that underwent the biopsies while the other 38.3% (23 patients) of the patient were having spinal tumor lesion. Fluoroscopic assisted percutaneous transpedicular biopsy shows higher percentage of sample accuracy with 86.6% as compared to Ct guided transpedicular biopsy with 80% accuracy. In terms of adequacy, fluoroscopic assisted percutaneous transpedicular biopsy has yield adequacy of 100% as compared with 93.3% adequacy of Ct-guided percutaneous transpedicular biopsy. Statistically otherwise show no significant different in both groups either for accuracy and adequacy.en_US
dc.description.identifierThesis : Accuracy and adequacy of fluoroscopic assissted percutaneous transpedicular biopsy in comparison to CT guided percutaneous transpedicular biopsy in spinal lesions /by Abdullah A Rahimen_US
dc.description.identityt11100424261AbdullahARahimen_US
dc.description.kulliyahKulliyyah of Medicineen_US
dc.description.nationalityMalaysianen_US
dc.description.notesThesis (MORTH)--International Islamic University Malaysia, 2019.en_US
dc.description.physicaldescriptionx, 33 leaves : colour illustrations ; 30cm.en_US
dc.description.programmeMaster of Orthopaedic Surgeryen_US
dc.identifier.urihttps://studentrepo.iium.edu.my/handle/123456789/10841
dc.language.isoenen_US
dc.publisherKuantan, Pahang : Kulliyyah of Medicine, International Islamic University Malaysia, 2019en_US
dc.titleAccuracy and adequacy of fluoroscopic assissted percutaneous transpedicular biopsy in comparison to CT guided percutaneous transpedicular biopsy in spinal lesionsen_US
dc.typeMaster Thesisen_US
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
t11100424261AbdullahARahim_24.pdf
Size:
591.99 KB
Format:
Adobe Portable Document Format
Description:
24 pages file
Loading...
Thumbnail Image
Name:
t11100424261AbdullahARahim_SEC.pdf
Size:
663.92 KB
Format:
Adobe Portable Document Format
Description:
Full text secured file

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description:

Collections