Repository logo
  • English
  • Deutsch
  • Español
  • Français
Log In
New user? Click here to register.
  1. Home
  2. Browse by Author

Browsing by Author "Siti Nurul Fatihah Azahan"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    Some of the metrics are blocked by your 
    consent settings
    Publication
    Investigation of paper-based sensor for sweat-based glucose detection using D-glucose solution
    (Kuantan, Pahang : Kulliyyah of Science, International Islamic University Malaysia, 2021, 2021)
    Siti Nurul Fatihah Azahan
    ;
    ;
    Mohd Hazimin Mohd Salleh, Ph.D
    ;
    Mohd Hamzah Mohd Nasir, Ph.D
    ;
    Ahmad Fakhrurrazi Ahmad Noordeen, Ph.D
    Diabetes is known as one of the chronic diseases caused by the insufficient insulin produced by the pancreas to convert glucose into energy. Monitoring glucose level using glucometer is very crucial for every diabetic patient in order to avoid other health problems. However, this procedure is painful and can cause finger pricking anxiety for some of the diabetic patient. As a replacement for this uncomfortable glucose monitoring procedure, researchers have introduced an inexpensive and user-friendly non-invasive paper-based sensor. This research aimed to investigate the application of paper-based glucose detection using sweat, by utilizing D-glucose solution. Approximately, 50 μL of glucose oxidase-peroxidase (GOD-POD) enzyme and 1.67 μL of glucose sample had been utilized for small scale detection. The limit of detection for this kit was recorded at 15.63 mg/L concentration of D-glucose. A specific microfluidic design with 1 cm diameter sensor area was printed on filter paper using Xerox wax printer. Glucose oxidase-peroxidase (GOD-POD) enzyme was immobilized on filter paper in order to react with 1.67 μL different concentrations of D-glucose solution to mimic the proportion of glucose in human sweat. The intensity of the colour changes resulted from the reaction between D-glucose solution and GOD-POD enzyme was measured using spectrometer. The wavelength shift range in between 4.12 nm to 34.9 nm were observed. The linear graph showed a clear correlation between D-glucose concentration and the wavelength shift.
      3

This site contains copyrighted unpublished research owned by International Islamic University Malaysia (IIUM) and(or) the owner of the research. No part of any material contained in or derived from any unpublished research may be used without written permission of the copyright holders or due acknowledgement.

Contact:
  • Dar al-Hikmah Library
    International Islamic University Malaysia (IIUM)
    P.O Box 10, 50728
    Kuala Lumpur
  • +603-64214829/4813
  • studentrepo@iium.edu.my
Follow Us:
Copyright © 2024: Dar al-Hikmah Library, IIUM
by CDSOL